LS3000H LS4000H LS5000 5000w energy power string inverter for soalr panels
Litto New Energy Co., Ltd: Responsible for INVERTER design; technology development; INVERTER assembly; quality inspection; sales service. And control quality of PCB, but processing external. Similar to Apple.
Introduction :
? Subline series LS3000H LS4000H LS5000
? TMS320F28062 DSP precision control.
? The most advanced MPPT Technology
? 1 or 2 independent MPPT tracker
? Advanced anti islanding scheme
? The maximum efficiency is as high as 97.8%, EU efficiency 97.0% THD~3%.
? The power factor adjustment range +/-0.9
Specification
Model name | LS 3000H | LS 4000H | LS 5000H |
DC input parameter | |||
Max. DC power | 3150W | 4200W | 5260W |
Max. DC power of per string | 3150W | 4200W | 5260W |
Max. DC voltage | 600Vdc | 600Vdc | 600Vdc |
Rated DC voltage | 360Vdc | 360Vdc | 360Vdc |
MPPT operationg voltage range | 100-550Vdc | 100-550Vdc | 100-550Vdc |
MPPT full load voltage range | 150-500Vdc | 200-500Vdc | 250-500Vdc |
parallel inputs number | 2 | 2 | 2 |
MPPT tracking number | 1 | 1 | 1 |
Max. input current | 23A | 23A | 23A |
DC connection type | MC4 terminal | MC4 terminal | MC4 terminal |
Maximum inverter backfeed current to array | 0A | 0A | 0A |
AC output parameters | |||
Max. output apparent power | 3000VA | 4000VA | 5000VA |
Rated output power | 3000W | 4000W | 4960W |
Rated grid voltage | 220V/230V/240Vac | 220V/230V/240Vac | 220V/230V/240Vac |
Gridvoltage range | 185V-276Vac | 185V-276Vac | 185V-276Vac |
Rated power grid frequency | 50 Hz/60Hz | 50Hz/60Hz | 50Hz/60Hz |
Grid frequency range | 45-55Hz/55-65Hz | 45-55Hz/55-65Hz | 45-55Hz/55-65Hz |
Max. output current | 15.0A | 20.0A | 25.0A |
Power factor (cos f) | 0.8i...i…0.8c | 0.8i...i…0.8c | 0.8i...i…0.8c |
Current harmonics (THDI) | <3%(under Rated output power) | <3%(under Rated output power) | <3%(under Rated output power) |
AC output terminal connection type | plug and play terminal | plug and play terminal | plug and play terminal |
Maximum output fault current | 80Arms | 80Arms | 80Arms |
Maximum output over current protection | Limited to 24A | Limited to 32A | Limited to 40A |
Efiiciency | |||
Max. efficiency | 97.50% | 97.80% | 97.60% |
EU efficiency | 97.00% | 97.20% | 97.10% |
MPPTefficiency | 99.80% | 99.80% | 99.80% |
General data | |||
(W / D / H) size | 355*395*170mm | ||
N.W | 16.5Kg | 17Kg | 17Kg |
Install way | Wall hanging fixed | ||
Operating temperature range | –25 °C ~ +60 °C | ||
Max. altitude | 2000m | ||
Relative temperature | 0%-98% No condensation | ||
Noise | =25 dB(A) |
Details
Safety distance
We recommend the inverter around have a minimum clearance, so that better to heat dissipation and wiring operation, as shown below:
The minimum clearance around the inverter
2.5 Installation steps
Step 1: punch 4 holes follows diagram 4.
Step 2:fix the bracket with screws, hang the inverter on the bracket.
Step 3: fasten on the top left corner and upper right corner with safety nut.
Step 4: check installation.
LS 3000H/LS 4000H/LS 5000H/LS 3000HD /LS 4000HD/LS 5000HD support bracket | Install the inverter onto the bracket |
Fix safety nut
Please check the following steps after complete the installation:
? Please do not install the inverter on the tilt panel
? In order to ensure the smooth installation of the inverter in the bracket, please check the top rope.
? Make sure that the screws are inserted from heat sink of the inverter and locked well.
? Check whether the inverter is fixed, please move the inverter from bottom-up, it should be firmly fixed still.
? Select a solid wall, to avoid vibration when inverter works.
Testing
Working Line
Application
Company Show
International Exhibition
Packing
FAQ:
Q: If i want to release order, what's the payment method you accept ?
A: We accept T/T, Paypal, Western union, L/C,Trade Assurance.
Q: How is the pacakge?
A: Packaged in carton box first. Then packing by Pallet.
Q: How to check inverter good or failure?
A: LCD show status. Monitor by PC or phone.
Q: Can inverter install with DC Switch? :
A: Yes, sure.DC switch is optional.
Q: What is inverter communication?
A: RS485.
- Solar Panel Power Energy Converter DC to AC 1 Pieces / (Min. Order)
- Top 10 On Grid Solar PV Solar System Inverter 1 Pieces / (Min. Order)
- TUV Certificate T and Y Branch MC4 Connector Prices 1 Pieces / (Min. Order)
- Y Branch Types Solar Panel 4mm 6mm 10mm MC4 Connectors 1 Pieces / (Min. Order)
- 6mm Contact PV MC4 MC3 Connectors Solar Tool Connections 1 Pieces / (Min. Order)
- Contact Panel Types Solar Panel MC4 Connector 1 Pieces / (Min. Order)
- Up to 32A DC Fuse Link with Holder 16A 1 Pieces / (Min. Order)
- DC Fuse 4 5 6 8 12A 1 Pieces / (Min. Order)
- SUP2 Type 2 2P 500V 40KA DC SPD in Voltage Function with TUV Certificate 1 Pieces / (Min. Order)
- 240 Volt 3kw 5kw Single Phase Solar Inveter Types Transfer DC to AC 1 Pieces / (Min. Order)
- On Gird Tie Solar Panel Inveter for PV System 1 Pieces / (Min. Order)
- Solar Panel Power Energy Converter DC to AC 1 Pieces / (Min. Order)
- Top 10 On Grid Solar PV Solar System Inverter 1 Pieces / (Min. Order)